CSCP — CloudScale Communication Protocol
CSCP command reference for Neutron: message structure, weighing, configuration, counting, checkweighing and digital I/O.
NEUTRON · USER MANUAL · v1.4
Configuration, wiring, communication and weighing procedures for Neutron CloudScaleLink and Neutron NS.
CSCP command reference for Neutron: message structure, weighing, configuration, counting, checkweighing and digital I/O.
Neutron Modbus RTU/TCP reference for PLC, SCADA and HMI integration: connection, addressing, registers, calibration and automatic checkweigher control.
OPC UA integration for Neutron: secure connections, live weighing data, stable capture and PLC/SCADA integration.
JavaScript application development for CloudScaleLink Neutron and CloudScale Neutron NS: runtime, weighing, digital I/O, settings, storage, communication modules and application management. Manual 1.0 · Neutron AppEngine 1.0.0 · API 1 · Publication date: 16 November 2026.
Neutron combines communication interfaces with optional local weighing and digital I/O. In CloudScaleLink mode, connect an existing scale, indicator or compatible serial device through UART, RS-232 or RS-485 and exchange data with Scale Monitor or other connected systems.
With the I/O board, Neutron provides four weighing channels through a multiplexed 24-bit ADC, up to 4,800 conversions per second, six digital inputs and six digital outputs. Wi-Fi and Bluetooth BLE are included; Ethernet requires the optional add-on.
CSL-NGP-WB — Wi-Fi and Bluetooth BLE, without Ethernet.
CSL-NGP-WBE — Ethernet, Wi-Fi and Bluetooth BLE.
Check the installed CPU board, I/O board and Ethernet option before wiring or configuring the module. The specifications below distinguish communication electronics from the NS weighing assembly.
Supply the CPU board with 5–24 V DC ±5%. Typical consumption at 5 V is 80 mA with Wi-Fi only, rising to approximately 100 mA during scanning. With Ethernet, typical consumption is 170 mA, with peaks up to 250 mA.
The I/O board takes power directly from the CPU board and adds approximately 15 mA plus the connected I/O load. The four-channel, 24-bit sigma-delta ADC has programmable digital filtering and up to 4,800 conversions per second. Internal/displayable resolution is up to 22 bits, approximately 4.2 million internal divisions, depending on filtering and update rate. The channels are multiplexed: only one channel is converted at a time.
Configure up to four scales independently: a freely entered measurement unit, multi-division or multi-range operation with up to three ranges, division and maximum capacity for each range, zero tracking, automatic zero on startup, filtering, stability divisions and stability window. Calibration supports up to eight additional linearization points per scale.
All dimensions are in millimetres. CloudScaleLink is the CPU-board assembly; Neutron NS combines the CPU and weighing I/O boards. Choose the drawing for the installed Ethernet option.
Model | Dimensions (L × W × H), mm |
|---|---|
CSL-NGP-WB | 71 × 40 × 13 |
CSL-NGP-WBE | 74 × 40 × 22 |
CS-NS-WB | 95 × 68 × 25 |
CS-NS-WBE | 95 × 68 × 35 |
CloudScaleLink: CSL-NGP-WB 71 × 40 × 13 mm; CSL-NGP-WBE with Ethernet 74 × 40 × 22 mm. Open the image to enlarge it.
Neutron NS: CS-NS-WB 95 × 68 × 25 mm; CS-NS-WBE with Ethernet 95 × 68 × 35 mm. Open the image to enlarge it.
Locate the reset button, multi-purpose MD button, RGB status indicator, SW1 UART/RS-232 selector, screw terminal block for power and serial connections, optional adapter power socket and U.FL / IPEX connector for the external 2.4 GHz antenna.
CloudScaleLink processor board components and connectors. Open the image to enlarge it.
Switch off Neutron and the connected device before wiring. Select the interface, set SW1 to match the connected device and wire the terminal block. After wiring, apply power and configure matching baud rate, data bits, parity, stop bits and protocol.
For RS-232, cross the transmit and receive lines and connect signal ground. For RS-485, connect A(+) and B(−), with signal ground where required by the installation.
Neutron NS terminal overview. RX and TX are the serial lines; B(−) and A(+) are the RS-485 lines; GND is ground and Vdc is power. Load-cell connections are on the right; digital inputs and outputs are on the left. When wiring, follow the individual terminal labels in the image and the relevant wiring diagram. Open the image to enlarge it.
Check the connected device's terminal assignments before wiring. RS-485 A/B naming can differ between manufacturers. If communication fails, first verify baud rate and protocol, then RS-232 TX/RX crossover or RS-485 polarity. The default serial settings are 9,600 bit/s, no parity and 8 data bits. Vdc+ is the external DC power input.
Each press of MD is acknowledged by the RGB indicator. Press the button the required number of times:
The MD button can be disabled in General settings.
Each module has a unique module ID (MID) and a factory PIN printed on its label. Use them to identify and access the module. You can change the PIN in the configuration utility. A factory reset restores the factory PIN.
Set the Device Name (DN) in General settings. Neutron converts it into a valid hostname; the mDNS name is that hostname followed by .local. If the device name is empty, MID is used.
Use the hostname for local access instead of entering the IP address.
CMP supports all module settings. Availability in the other utilities depends on the particular function.
Bluetooth and Wi-Fi are enabled by default. In General settings, choose Wi-Fi or Ethernet for internet and LAN communication. Ethernet appears only when the optional Ethernet hardware is installed. Disable the network communication interface if the module will operate through Bluetooth only.
With firmware 1.7 or later, enable several interfaces simultaneously under Scale communication interface, each with its own protocol and settings. Depending on hardware and firmware, the choices include Bluetooth, UART/RS-232, RS-485, TCP, WebSocket, HTTP/REST, Cloud Scales/MQTT, Cloud, Modbus TCP and Disabled.
Examples: RS-232 plus Cloud Scales for a scale and PC/cloud connection; Modbus TCP over Ethernet/Wi-Fi for a PLC or SCADA; Modbus RTU over a serial line; Bluetooth for a local mobile application; TCP, WebSocket or HTTP/REST for custom software. Enable only the interfaces required for the installation.
Connect Neutron to a 2.4 GHz Wi-Fi network using the BLE tool or its access point. Prepare the SSID, credentials and, if needed, network settings and certificates.
On iPhone or iPad, use a browser with Web BLE support, such as Bluefy.
If connection fails, reconnect through the access point and check the saved settings.
Choose Scan and select a network from the results. Selecting a network also fills its BSSID; clear it if the installation requires roaming between access points with the same SSID. Scanning is unavailable while Neutron is trying to establish its Wi-Fi connection.
Signal strength is shown in dBm. A value closer to zero is stronger: −40 dBm is stronger than −70 dBm. Indicative levels: −30 to −50 excellent; −50 to −60 very good; −60 to −70 good; −70 to −80 weak; −80 to −90 very weak; below −90 unreliable.
For an open network, enter SSID and set Encryption to None; leave the password empty. Open networks do not encrypt traffic and are suitable only where that limitation is acceptable, such as isolated testing.
For a password-protected network, enter SSID and Password and set Encryption to WPA2/WPA3. These networks use a pre-shared key and do not require a RADIUS server.
With DHCP, the device obtains network settings automatically. For a static configuration, enter IP Address, Subnet Mask, Gateway and DNS.
Wi-Fi Enterprise and Ethernet 802.1X offer the same four authentication methods. Neutron acts as the client or supplicant. The access point or switch forwards authentication to the RADIUS server. RADIUS shared secret is configured between the access point or switch and RADIUS; do not enter it in Neutron.
Upload certificates and the key in PEM format. Use an unencrypted PEM private key that matches the client certificate. An empty upload field after opening the page does not mean the device has no certificate. Leaving the field untouched preserves the existing certificate.
Ethernet 802.1X requires a CA certificate. Wi-Fi can authenticate without a CA when name and date verification are both disabled. Wi-Fi requires a CA certificate to verify names or dates.
Leaving RADIUS certificate DNS name empty disables name verification but preserves verification against the configured CA. If entered, the name is checked against the RADIUS server certificate. Find it in the server certificate under Subject Alternative Name → DNS Name, not in the CA or client certificate. Enter only the name, without https:// or a port, for example radius.example.com.
When Verify certificate dates is enabled, the device clock must already be correct before authentication. NTP that becomes reachable only after login cannot set the clock for initial authentication through a closed network port. Disabling date verification preserves verification against the configured CA and server name. For compatibility, Wi-Fi defaults to date verification disabled. Existing saved settings are preserved on upgrade.
TIMEOUT may also accompany a failed TLS exchange. Use logs from Neutron, the access point and RADIUS for diagnostics. Application status messages are visible at debug level Info or higher.
BSSID is the MAC address of one specific access point. Enter it to restrict Neutron to that access point; scanning and selecting a network fills it automatically. Do not set BSSID when the module must roam between multiple access points sharing one SSID: a fixed BSSID prevents roaming and may cause weak or lost connectivity.
Available with firmware 1.8.3 or later. In Wi-Fi settings, select the country where the device is physically installed, save and reboot if requested. The default is EU – Europe. Country selection controls permitted Wi-Fi channels and transmit-power limits. Do not select another region to obtain additional channels or power. Update this setting if the module is moved permanently to another country.
Available with firmware 1.8.3 or later. Use Auto unless the installation requires a specific value; firmware and country settings determine the permitted output. Selectable settings and approximate power: 20 dBm / 100 mW; 18 / 63; 15 / 32; 13 / 20; 11 / 13; 8.5 / 7; 7 / 5; 5 / 3; 2 / 1.6.
Higher power may improve range but increases consumption, interference and coverage outside the intended area. Reduce power when the access point is close, many modules share the area, or limited coverage and lower consumption are required. The selectable range is 2–20 dBm; actual permitted output also depends on country and channel. Configure Country of use first.
Ethernet requires the optional CS-NA-ETH module. The Ethernet menu is unavailable if the module is absent or not working.
The methods and fields are the same as for Wi-Fi Enterprise in section 8.6. A CA certificate is mandatory for every Ethernet 802.1X method. See section 8.6 for certificates, name verification and date verification.
A physical link and an assigned IP address alone do not prove successful 802.1X authentication. AUTHORIZED confirms successful authentication.
TIMEOUT may also accompany a failed TLS exchange. Use logs from Neutron, the switch and RADIUS for diagnostics. Application status messages are visible at debug level Info or higher.
Serial Port 1 operates as UART or RS-232; Serial Port 2 provides RS-485. Use either port to bridge an existing serial device, or to communicate with the local weighing electronics.
For each port, set Serial redirect to Disabled, Cloud, WebSocket, Bluetooth, HTTP or TCP. To communicate with the scale on the I/O board through a serial port, leave its redirection disabled.
Serial Port 1 defaults to RS-232. Configure redirection, baud rate, data bits and parity. Available baud rates are 1,200, 2,400, 4,800, 9,600, 19,200, 38,400, 57,600 and 115,200 bit/s; choose 7 or 8 data bits and no, even or odd parity. Select CR, LF, CRLF or up to two custom ASCII characters as the string terminator. Choose whether to append that terminator automatically when forwarding data to the serial port.
Switch off Neutron before changing SW1. Match SW1 to the electrical interface of the connected device. Connecting a UART device while SW1 is set to RS-232 can damage that device; connecting an RS-232 device while SW1 is set to UART can damage Neutron.
Confirm the device pinout and SW1 position before applying power.
Use Serial Port 2 for differential RS-485 communication, including a shared bus with several devices and one master. Supported distance is up to 1,200 m with the specified cable and suitable installation conditions. Neutron controls switching between transmission and reception automatically.
Configure redirection, RS-485 address (0–255), baud rate, 7/8 data bits, parity and terminator. Baud rates and terminator choices are the same as UART/RS-232; automatic terminator appending is optional.
Connect Neutron A(+) to the external device or bus A(+), and B(−) to B(−). Connect signal ground where required. Check the manufacturer's polarity convention if A/B names differ.
Available with firmware 1.8 or later. Under Scale communication interface, enable RS-232 or RS-485 for Modbus RTU. Match baud rate, data bits, parity, stop bits and Modbus slave address / Unit ID to the master. Set the address with MBA; the default is 1.
For RS-232, connect TX to RX, RX to TX and signal ground; check DTE/DCE pin assignments. For RS-485, connect A(+), B(−) and ground where needed. Use a daisy-chain bus, not star wiring, and terminate only at the two physical ends where termination is required.
If communication fails, check A/B polarity, serial parameters and Unit ID. Open the Modbus RTU/TCP manual for the register map, functions, commands, data formats and calibration interface.
In Cloud settings, enable the connection and select its transport. If Cloud is disabled, Neutron does not connect to the broker and remote cloud management is unavailable.
For WSS or MQTTS, provide the appropriate CA certificate when the broker uses a self-signed certificate or an authority not already trusted. A valid trusted chain is needed to verify broker identity.
Enter Server (hostname or IP), Port and Client ID; the default Client ID is MID. Credentials options are Built-in for Scale Monitor, Custom for your username/password, and None when no username/password is required or mTLS is used.
For unreliable links, consider QoS 1. Use QoS 2 only when required rather than for continuous high-rate communication. Group topic and Group topic without SN/MID are manufacturer settings.
Replace MID with the module ID. Neutron subscribes to RX topics for commands and publishes data or responses to TX topics; it does not publish commands on RX or subscribe to TX.
For Wi-Fi startup and connection diagnostics, use Bluetooth debugging.
Open apps.scale-monitor.com and select MQTT client. Connect to the intended broker, subscribe to the module's TX topics and publish test commands to the corresponding RX topics.
Connect Neutron to AWS IoT Core with MQTT over TLS and X.509 client-certificate authentication. Prepare a Thing, its certificate and private key, a suitable IoT policy and the account's device endpoint.
In IoT Core, open Security → Policies and edit the policy attached to the device certificate. Allow iot:Connect for the intended Client ID, iot:Publish and iot:Receive for the required topics, and iot:Subscribe for their topic filters. Restrict resources to your account, region and module.
In the AWS connection mode, the device example uses CSL/MID/… topics. Include the required AWS topics only for the functions you use. Set the edited policy version active and save it. Do not copy another account's ARN or use unrestricted * resources for a production installation.
In this template, replace REGION, ACCOUNT_ID and MID with your region, account and device identifier. Add only the additional AWS topics required by your application.
{
"Version": "2012-10-17",
"Statement": [
{
"Effect": "Allow",
"Action": "iot:Connect",
"Resource": "arn:aws:iot:REGION:ACCOUNT_ID:client/MID"
},
{
"Effect": "Allow",
"Action": [
"iot:Publish",
"iot:Receive"
],
"Resource": "arn:aws:iot:REGION:ACCOUNT_ID:topic/CSL/MID/*"
},
{
"Effect": "Allow",
"Action": "iot:Subscribe",
"Resource": "arn:aws:iot:REGION:ACCOUNT_ID:topicfilter/CSL/MID/*"
}
]
}If connection fails, use Bluetooth debugging to inspect the connection messages.
In IoT Core, open Test → MQTT test client. Replace MID with the module ID, subscribe to CSL/MID/TX and publish a command to CSL/MID/RX. Check the response on TX. For other interfaces, use their corresponding topic suffixes.
Neutron supports Azure IoT Hub over MQTTS with SAS-token authentication or the supported X.509 mode. In this implementation, use only one cloud bridge at a time. When several are enabled, the processing priority is scale, then RS-232, then RS-485; lower-priority bridges are ignored.
If using the X.509 option instead, select the matching MQTTS X.509 mode and upload the required certificates and key.
Use Azure IoT Explorer. Open the device, start telemetry monitoring and send a cloud-to-device message containing the command for Neutron. Check the responses in the telemetry view.
Use WebSocket for bidirectional communication with a remote server. For serial bridging, choose WebSocket under Serial redirect. For the local scale, select WebSocket under Scale communication interface. Both WS and encrypted WSS are supported, with optional HTTP Basic Authentication.
Disabled prevents a WebSocket connection. WS uses unencrypted TCP and is intended for trusted local networks. WSS uses TLS encryption and is the appropriate choice for public networks and cloud servers.
In WSS mode, set Allow insecure SSL connection to No to validate the server certificate against the configured CA. Yes accepts certificates without validation and significantly reduces security; use it only for controlled testing or troubleshooting.
Upload the CA certificate in PEM format to verify the server's TLS certificate. It is required for WSS when insecure connections are not allowed.
Enter the WebSocket server hostname or IP address, for example ws.example.com or 192.168.1.100.
Enter the server's TCP port: typically 80 for WS, 443 for WSS, or the custom port configured on the server.
Enter the WebSocket endpoint path, such as /, /ws or the path required by the server. An empty field uses the root path /.
Enable Use Basic Authentication when the server requires a username and password during the WebSocket handshake. Enter both credentials. If disabled, these credentials are not sent.
The internal web server provides module configuration and REST bridging to serial ports or the local scale. HTTPS is enabled by default on port 443 with a self-signed certificate. Log in with the module PIN. HTTPS can be disabled in HTTP settings; setting the port to 0 disables the web server completely.
Use the configured scheme, IP/hostname and port, for example https://192.168.50.79, https://t7bw2j.local, or http://192.168.50.79:8080 when HTTP is explicitly configured on port 8080. A self-signed certificate may trigger a browser warning until its CA is trusted and the hostname matches.
Use an organizational or trusted CA certificate where required by your installation.
Both certificate trust and hostname matching are required to avoid validation warnings.
For serial access, set Serial redirect to HTTP. For the I/O-board scale, set its communication interface to HTTP. Otherwise the corresponding endpoint returns 404.
The module waits up to 5 seconds for a device response and returns it in the HTTP body. If nothing arrives, the body contains [no serial response] or [no scale response].
Set an optional token in the HTTP tab. When enabled, include the tok parameter in GET and POST requests. The maximum token length is 128 ASCII characters. Percent-encode reserved characters when constructing a URL, especially &, = and #; a raw # starts a fragment and is not sent to the server.
Example with placeholders: https://MODULE-IP/SC/?cmd=SXI&tok=YOUR-ENCODED-TOKEN. Keep your actual token confidential.
Pass the command in cmd, for example https://MODULE-IP/S1/?cmd=data. Use S2 or SC for the other interface and add tok when token protection is enabled.
Send the data in the POST body, either as plain data or through the cmd parameter. The module forwards it to the selected serial port or scale endpoint. Include tok if configured.
Enable or disable Bluetooth in its settings. To bridge a serial port, select Bluetooth under that port's Serial redirect setting. Configure the string terminator where needed.
Use these UUIDs in a BLE application:
In General settings, set Debug interface to Bluetooth and reboot. A flashing blue RGB LED means Neutron is waiting for a Bluetooth connection before starting Wi-Fi, Ethernet, I/O and other interfaces, so startup messages can be captured.
The wait is up to 30 seconds. If no client connects, normal startup continues; debugging messages remain available after a later connection. Use the BLE utility and its Bluetooth tab. A local BLE connection also supports diagnostics when Neutron has no internet connection. Remote support additionally depends on connectivity of the device running the utility.
Set the selected serial port's redirection to Bluetooth. In the BLE utility's Bluetooth tab, enter data in Command and choose Send. Neutron forwards it to the serial device; replies appear in Received.
In the TCP tab, select Server, Client or Server & Client. Configure each enabled mode separately.
Neutron listens for incoming connections on its configured TCP port. The default is 10010. The external system connects to the module's IP address and this port.
With TCP server port exclusive enabled, an existing connection causes new connection attempts to be rejected. With it disabled, a new connection replaces and disconnects the existing one.
Enter the destination IP address and TCP port. Neutron initiates the connection and automatically attempts to reconnect after connection loss, for example following a Wi-Fi interruption or server outage.
Enable Bridge to cloud for the TCP server, client or both. Data received through TCP is forwarded to the cloud, and cloud data is sent back through TCP. Configure server and client redirection independently. Use this for TCP-capable equipment such as network scales and label printers. Application-level bridge details are available with the CSL API documentation.
The printer can then send supported print confirmations and alerts, such as out of labels, no ribbon or open cover, back to Scale Monitor.
Available with firmware 1.8 or later. Modbus TCP provides PLC, SCADA, HMI, MES and custom software with access to weighing values, scale state, I/O, commands and supported calibration data.
Use Ethernet where a wired connection is available; check Wi-Fi latency under actual operating conditions. Modbus TCP can run alongside other enabled interfaces, such as a serial scale connection. Open the Modbus RTU/TCP manual for the shared register map and command handling. For OPC UA integration, use the OPC UA manual.
The I/O board adds four multiplexed 24-bit weighing channels, six digital inputs and six digital outputs. Inputs can count up to 1,000 Hz. Configure digital I/O using the BLE utility or CMP. Use the appropriate communication API for commands, input states and counter values.
Open the I/O dashboard to view current input and output states. Choose an input's gear icon and select ON/OFF or Counter mode.
Set the debounce filter: the signal must remain stable for this time before a change is accepted. Typical settings are 5–100 ms.
Use inputs 1–4 for counters. Set the glitch filter to reject noise pulses shorter than the selected duration; typical settings are 1–20 µs. This filter applies only in Counter mode. Up to four counters can be active simultaneously.
Change outputs manually through commands, BLE or CMP, or assign an automatic function. Open the output gear icon, select the required function and save. Automatic functions can follow weighing tolerance or dosing states.
The I/O board provides four independently configurable weighing channels through a multiplexed 24-bit ADC, with up to 4,800 conversions per second. Conversion takes place on one channel at a time.
Depending on configuration, communicate through UART/RS-232, RS-485, BLE 5.0, MQTT over TCP or secure WSS, WebSocket WS/WSS, or HTTP/REST.
Open the CSCP manual for scale commands, Modbus RTU/TCP for registers and PLC communication, or OPC UA for the server model and integration.
The calibration menu provides Tare, Clear tare, Zero and Temperature. TEMP displays the ADC internal temperature. Weighing conversion is temporarily suspended while temperature is measured.
Select the Channel field and choose the required channel. Its settings are loaded automatically.
For the selected channel, enter the measurement Unit, such as kg, g, t, mg or lb, or your own unit text. Select one to three weighing ranges and the required Multi-division or Multi-range mode. Set the divisions d1–d3 and maximum capacities Max1–Max3 for the corresponding ranges.
Calibrate zero first. Then add up to eight linearization points for the selected scale.
For each point, enter the mass of the load to be placed on the receptor, apply that load and choose Calibrate. Increase the load for every subsequent point. A lower load than the previous point decreases the ADC value and causes a calibration error.
Read the Net field: CS means calibration starting; C1–C10 counts attempts while waiting for a stable signal; CF means completed successfully; CE means an error.
If stability is not reached after 10 attempts, repeat the point under more stable conditions. The option Do not check stability bypasses stability verification and can store an unstable point; use it only when that behaviour is intentional.
For manual calibration or fine adjustment, enter the ADC values and calibration factors directly.
The stability window adds a time check after the divisions-based stability condition has been reached:
If weight changes during the window, stable status is not released. Use Medium or Slow for high-resolution scales; Quick can suit standard-resolution scales up to 10,000 divisions in stable conditions. Wait ADC is reserved for manufacturer use and should remain disabled during normal operation.
Register at register.scale-monitor.com and sign in to CMP. Manage activated modules with cloud management enabled and an internet connection. CMP provides connection status, Wi-Fi signal, connectivity tests, LED identification, remote reboot, configuration and communication debugging.
The list shows modules activated in your CMP account. Choose Ping all modules to request their current status; offline modules are indicated. Open an individual module for connection tests, configuration or debugging.
Adding a scale in Scale Monitor also activates its module in CMP. Once activated in your account, another account cannot activate the same module until you deactivate it.
Choose Deactivate module, enter the requested module details and confirm. The module is removed from your account's list and can then be activated in another account.
Choose Settings. If the module is online, CMP establishes the configuration connection. Change the required settings, such as IP configuration or DHCP, and save. Reboot when the selected setting requires it.
The debugger displays communication between the module, serial device and connected software/cloud. Sent commands appear green, received messages orange and errors pink. Enter a command in the command panel and send it to inspect the device response.
Choose Add to create a command field, enter the command and choose its Send button. Use X beside the field to delete that command.
Open System resources to monitor uptime, CPU load, memory and the counts of Wi-Fi/Ethernet disconnections and lost IP addresses since startup.
Connect to Neutron through the BLE utility on your phone or another Bluetooth-capable device and choose Request virtual assistance. When support accepts the request, use the chat while the assistant inspects and diagnoses the module. The device running the utility needs the connection required to reach support.
Configuration access is blocked during assistance to avoid conflicting changes and is restored when the session ends.
Check power, wiring, network status and the relevant interface settings before changing several settings at once. Use Bluetooth debugging for startup and network diagnostics.
Scanning cannot run at the same time as a Wi-Fi connection attempt. If Wi-Fi is selected as the communication interface and the module is still trying to connect, scanning is temporarily unavailable.
Use the factory PIN printed on the module label. Changing the module PIN does not change the access-point password.
No. The ADC is multiplexed and converts one channel at a time. Configure the channels separately.
Use the CSCP manual for scale commands, the Modbus RTU/TCP manual for its register map, and the OPC UA manual for the server model. Direct links are in chapter 18 and the protocol cards.
Need help with software, connectivity or using a solution? Describe the issue so we can help with the next step.