WEIGHING TECHNOLOGY · IN-HOUSE DEVELOPMENT · SUPPORT
+386 2 320 33 46info@preciz.si
PRECIZWeighing technology.
Connected to your process.

Neutron now with an OPC UA server: connect weighing to your system

Neutron with an OPC UA server is an ideal connection point for automated dosing, weight checking and inventory monitoring, including silos. Your PLC, SCADA or application receives weighing data while free Scale Monitor Cloud can provide remote monitoring and management at the same time.

18 October 2026 · Integrations

Neutron NS weighing electronics.
Neutron NS weighing electronics.
OPC UA logo.
Neutron NT weighing terminal with a touchscreen.
Neutron NT weighing terminal with a touchscreen.

When weighing data is needed in several places, manual copying slows work and increases the chance of errors. OPC UA connects the weighing station to the system that uses its data: a control-room display, a production record or your own application.

Who is OPC UA for?

Manufacturers, machine builders, integrators, automation teams and IT specialists. It is particularly useful where a PLC, SCADA, MES or PC application already supports an OPC UA client.

From automated dosing to inventory monitoring

Example dosing machine for filling material into bags.

Automated dosing

Connect weight data to the PLC or control application that manages filling and discharge. OPC UA provides access to live measurements and permitted scale functions.

PB platform scale with a Neutron NT terminal displaying weight checking.

Weight checking

Use measured weight to check products or packages. Your system compares it with the target and tolerances, then retrieves a stable result for the inspection record.

Silo Monitor: silos, Neutron electronics and an inventory overview.

Silo inventory

Monitor the weight of material in a silo, tank or hopper through SCADA or your own application. Inventory visibility helps you plan replenishment and material deliveries in time.

How the connection works

Weighing platform

Load cells provide the measurement signal to the Neutron weighing electronics.

Neutron NS or NT

The OPC UA server in Neutron provides weighing data and supported methods.

Your system

A PLC, SCADA, MES or application with an OPC UA client connects to Neutron over the network. The Scale Monitor cloud connection can run simultaneously.

OPC UA and cloud – together, without choosing

Neutron supports simultaneous OPC UA and Scale Monitor Cloud connections. The local PLC or SCADA uses weighing data for your process, while free Scale Monitor Cloud provides ongoing remote device monitoring and settings management whenever an internet connection is available.

Combine on-site automation with remote supervision and support. Using OPC UA does not mean giving up cloud capabilities.

Compact NS fits into your equipment

The compact Neutron NS is easy to integrate into a control cabinet, scale housing, diverter or other machinery. Connect weighing to control systems and the cloud without installing a separate touchscreen terminal beside the equipment.

One example is the FKN floor scale with integrated Neutron NS: the weighing electronics are built into the scale and data is available to the connected system.

FKN floor scale with integrated Neutron NS.
Installation example: FKN floor scale with integrated Neutron NS.
Explore FKN with Neutron NS

What does Neutron support?

  • Live weighing data: gross, net and tare weight, high-resolution gross weight, stability, status, error code, unit and ADC value.
  • Consistent measurements: read a combined data snapshot with ReadMeasurement, or capture stable weight with CaptureStableWeight and retrieve it through GetCapturedMeasurement.
  • Scale control: tare, preset tare, zero, clear tare and filter settings, according to the assigned permissions.
  • Information model: named nodes and methods, with a NodeSet2 XML model for integration tools.

Connections with or without encryption

Neutron supports encrypted Basic256Sha256 / SignAndEncrypt connections with a username, password and trusted application certificates. An unprotected None / Anonymous mode is also available. Configure the connection mode and user permissions to match your network requirements.

The features described apply to Neutron firmware 2.5.0 with OPC UA support. Use the local OPC UA connection on its own or simultaneously with Scale Monitor.

Use the detailed OPC UA manual for connection setup, the node list, security settings and method-call examples.

Open the OPC UA manual

Choose Neutron for your weighing station

Neutron NS weighing electronics.

Neutron NS – for embedded and connected systems

Compact displayless weighing electronics for installation in a control cabinet, scale, diverter or machine. Choose NS when your own system provides the display and workflow.

Neutron NS in the online shop
Neutron NT weighing terminal with a touchscreen.

Neutron NT – weighing with a touchscreen interface

A touchscreen weighing terminal for operators at the weighing station. Combine local operation and weighing applications with a connection to your own system.

Neutron NT in the online shop

Frequently asked questions

What must my system support?

Your PLC, SCADA, MES or application needs an OPC UA client. Neutron acts as the OPC UA server in the connection.

Can OPC UA and Scale Monitor run at the same time?

Yes. Neutron supports simultaneous OPC UA and cloud connections. Your local system uses weighing data while free Scale Monitor Cloud provides remote monitoring and settings management over an internet connection.

Does Neutron support encrypted connections?

Yes. It supports Basic256Sha256 / SignAndEncrypt, a username and password, and trusted application certificates. An unprotected None / Anonymous mode is also available.