Target, progress and dosing stage
One screen shows the current weight, target and remaining quantity, selected formula and cycle. The status bar identifies the dosing stage, while pause and stop controls let the operator intervene.
Dose material at three speeds and repeat batches using a saved formula. Neutron NT combines dosing control, automatic in-flight material compensation and container checks, letting you adapt the process to the material, quantity and required accuracy.
One screen shows the current weight, target and remaining quantity, selected formula and cycle. The status bar identifies the dosing stage, while pause and stop controls let the operator intervene.
Three dosing speeds allow a fast initial feed followed by progressively reduced flow as the target approaches. The application controls feeding through Neutron outputs and completes the cycle automatically.
Material still falling into the container after the feed closes is accounted for as in-flight material. Advanced automatic correction algorithms adjust this compensation for accurate dosing across repeated batches.
Save formulas for different materials and target quantities, then reuse them in daily work. Cyclic dosing supports multiple consecutive batches using the selected process.
Enable automatic taring and set minimum and maximum permitted tare values. This adds a check that the correct container, bag, cylinder or other packaging has been selected before dosing.
Set the maximum permitted dosing time as an additional process safeguard. The time limit helps constrain an abnormally long cycle.
The operator can pause dosing temporarily or stop it. Process status, weight and cycle data remain clearly visible on the screen.
Select the saved formula, target weight and cycles. Use automatic taring and, where required, minimum and maximum tare checks.
Feeding progresses through fast, medium and slow stages. In-flight material compensation accounts for material that reaches the container after the feed closes.
The application completes the cycle automatically. Repeated batches use cyclic dosing, while results and parameters are available in weighing history.
When filling bags with cocoa, select a formula and a 5 kg target. Tare checks help identify the correct empty bag, three speeds and in-flight compensation control feeding, and cycles support subsequent batches.
Define the material, target weight, tolerance, feeding method and packaging type when selecting a solution. Distributors can demonstrate the complete cycle: container checks, taring, three speeds, in-flight compensation and the saved result.
The applications run locally on the Neutron NT terminal, so the weighing process does not depend on a continuous internet connection. Measurements are saved automatically to the SD card and, when connected, to Scale Monitor Cloud. The free web application also lets you edit indicator screens, databases, dynamic fields and print layouts.
Measurements are saved automatically to the local SD card and, when connected, to Scale Monitor Cloud. Choose which fields appear in the history table and tailor the view to your application, products and daily information needs.
Open a saved weighing to see all its parameters. A dosing record includes the formula, target, achieved weight, cycle and elapsed time, so you can review the result alongside the settings used to produce it.
Use the free Scale Monitor Cloud web application to adapt Neutron NT to your process quickly and easily. Customise the entire indicator screen, create your own databases and dynamic fields, and design receipts or labels.
Use the graphical editor to customise the layout, appearance, buttons and displayed data without programming. Show operators the information they need for the application they are using.
Create product, customer or other databases for your workstation. Import data from Excel or integrate databases with other systems through the REST API to reduce manual re-entry.
Add your own fields, such as batch, work order or an extra identifier. Set the field name, data type and default value, and choose whether an entry is required before saving.
Use the free Scale Monitor Cloud editor to design POS receipts or packaging labels. Arrange weighing data, text, a logo, barcodes or QR codes and your own dynamic fields.
Extend the workstation to suit the job: select a product by barcode, identify an operator with RFID, label the packaging or capture a photograph when a weighing is saved.
Label packaging with weight, piece count, product, batch, operator and machine-readable codes. Fully customise the layout in the free Scale Monitor Cloud application.
View the label printerPrint a weighing ticket or receipt with measurement and process data. Design its contents and layout in the free Scale Monitor Cloud editor.
View the POS printerScan a 1D or 2D code to select a product, enter a batch or identify an order. The industrial SM-BS1D2D-IGD connects directly to Neutron NT over Bluetooth.
View the barcode readerCapture a photograph when a weighing is saved. Add a visual record of the material, product or packaging to the weight record for later review.
View the cameraIdentify an operator with a contactless badge. The embedded NFC/RFID reader simplifies operator identification at the workstation and associates the task with the identified user.
View the NFC/RFID readerThe application supports fast, medium and slow dosing, with automatic in-flight material compensation and cyclic dosing.
Enable automatic taring and define minimum and maximum permitted tare values to add a check for the selected container, bag, cylinder or other packaging.
Yes. The operator can pause the process temporarily or stop it. A maximum dosing time can also be configured as an additional safeguard.
Tell us what you weigh, the quantities you handle and the data you need with each result. We will propose a solution for your workstation.